IV. Specic Requirements
1. EVOLUTION 6000 Plus TIC
SENSOR:
TYPE
ARRAY SIZE
SPECTRAL RESPONSE
NETD
DYNAMIC RANGE
VIDEO STANDARD
FRAME RATE
VIDEO OUTPUT
Uncooled vanadium oxide microbolometer focal plane array detector
320X240
7.0-14.0 microns
≤78mK (.078°C) max. ≤40mK (.040°C) typ. (in High Sensitivity), ≤234mK (.234°C) (in Low Sensitivity)
-40° to 320°F (-40° to 160°C) (in High Sensitivity), -40°F to 1112°F, (-40°C to 600°C) (in Low Sensitivity)
BT-656 digital
60 Hz
.mv4 (.mpeg4)
MECHANICAL:
DIMENSIONS
BASE WEIGHT
MATERIALS
OUTER HOUSING
RUBBER BUMPERS
DISPLAY COVER
BUOYANCY
7.3'' x 4.8'' x 11.6'' (185 mm x 122 mm x 295 mm)
42.4 oz. (2.65 lbs/1.2 kg)
Outer case and bumper materials pass NFPA 1801, 2013 Edition direct ame and heat exposure tests
Polyphenylsulfone
Flame-retardant silicone
UV-stabilized polycarbonate with NFPA anti-scratch coating
Camera oats in water
ELECTRICAL:
POWER SUPPLY
POWER CONSUMPTION
USB PORTS
DISPLAY
Supplied by integral battery pack
<6 W nominal
1 conguration port (E6000, E6000+), 1 conguration, 1 video/image download port (E6000X)
3.5" LCD backlit display
ENVIRONMENTAL
AMBIENT TEMP:
80º C, 176º F
120º C, 248º F
260º C, 500º F
30º C, 22º F
40º C, 40º F
OPERATING TIME:
> 30 minutes
> 20 minutes
> 6 minutes
> 40 minutes
> 25 minutes
WATER/DUST INGRESS: TIC shall resist dust and water and must conform to International Standard CEI IEC 529;
Degrees of Protection Provided by Enclosures (IP Code); IP67 classication
IMPACT/DROP: Will survive 6-ft (2-m) drop at any angle with no operational defaults or physical compromise of outer housing
RFI/EMC: TIC should not interfere with standard reghter frequency bands at power levels found in hand-held (3-5W) and vehicle-
mounted systems (~100W). Communication/electronic devices cannot aect TIC to the point where navigation is compromised
when TIC is subjected to RF interference of 80 MHz to 1 GHz at 30V/m. TIC must meet RFI emissions and susceptibility of IEC
OPTICAL:
LENS
FIELD OF VIEW
FOCUS
DIGITAL ZOOM
9mm, F1.25
48° horizontal, 37° vertical
Optimal 3 ft to ∞ (1m to ∞)
2X and 4X
BATTERY STATUS:
4 GREEN
3 GREEN
2 YELLOW
1 RED
1 RED FLASHING
SHUTTER INDICATOR
LOW SENSITIVITY INDICATOR
Total battery capacity will be indicated in viewing area with row of 4 LEDs, functioning as follows:
75% to 100% capacity
50% to 75% capacity
25% to 50% capacity
Less than 25% capacity
Less than 5 minutes remaining
On-screen indicator appearing as small block in upper left display corner when camera shutters indicates that area re-scan is necessary.
On-screen indicator appearing as green triangle in upper left display indicates activities when TIC is in Low Sensitivity
OVERTEMPERATURE WARNING:
NOT LIT
FLASHING RED
On-screen red triangle in display's upper center
TIC is within operational thermal limits
TIC has exceeded recommended operational thermal limits